Search results for " TECNICA"
showing 10 items of 2030 documents
A set of indices to assess the real performance of daylight-linked control systems
2017
Abstract The installation of Building Automation Control Systems (BACs) in general is an effective action to achieve relevant energy savings. Commercial BACs, installed in residential or small offices, often include functions of lighting control, acting as Daylight-Linked Control Systems (DLCSs). Nevertheless, because system performance is strictly dependent on different parameters, BAC’s hardware and software configuration and as well as an inaccurate commissioning do not always allow a perfect execution of the desired tasks; therefore, the system could not work as expected. Moreover, it is well known that energy saving potential is specifically related to the variability of the light envi…
Interaction between Longitudinal Shear and Transverse Bending in Prestressed Concrete Box Girders
2017
In box girder bridges, the quantity and distribution of reinforcement to be put in concrete elements of sections can be evaluated only by considering the deformation of the cross section in addition to the longitudinal analysis of the static scheme, establishing the entire state of stress of box sections. This leads to a need to evaluate the interaction between internal forces obtained by the global analysis and the ones obtained by the local analysis of the cross sections. The frame effect implies the elastic deformation of slabs and webs, whereas eccentrically applied loads lead to cross-section distortion with the loss of the box shape. Hence, the reinforcement is strongly influenced by …
Comparative experimental analysis on the compressive behaviour of masonry columns strengthened by FRP, BFRCM or steel wires
2017
Abstract In the last decade, several studies have investigated the application of Fibre Reinforced Polymer (FRP) wraps to masonry piers in order to provide a confinement effect and enhance compressive strength and ductility. Although this technique has proved to be quite effective, various drawbacks arise when organic resins are used to bind fibres. To solve these problems, different techniques have been developed to be used as alternative methods for enhancing the structural performances of weak masonry columns. Among these, the use of Basalt Fibre Reinforced Cementitious Matrix (BFRCM) wrapping, or the application of steel wires at mortar joints. This paper presents the results of an expe…
The overall classification of residential buildings: Possible role of tourist EU Ecolabel award scheme
2012
Abstract The debate on the environmental performance of buildings and their classification is continuously rising and deeply involves all actors of the sector, from researchers to technicians and from owners to real estate managers. In the field, the EU has created a panel that is currently working on defining the criteria for attributing an Ecolabel award to a building. However, despite the enormous efforts made by administrative and academic institutions, a suitable and widely available scheme for operators to assess the environmental performance of a building is far from being established. To help provide a solution to the problem, the possibility of adopting the EU Ecolabel scheme estab…
Simplified equivalent finite element modelling of concrete-filled steel tubular K-joints with and without studs
2022
Concrete Filled Steel Tubular (CFST) K-joints employed for truss structures gained high interest in the last years due to their widespread use in engineering practice. The overall performances of these joints can be efficiently improved by using steel studs welded in the inner surface of the steel chord filled with the concrete, avoiding punching shear failure, and improving the overall strength and ductility. However, a reliable prediction of the structural behavior of the joints is outmost of importance for the assessment of the capacity of new and existing structures, and there are no standardized design methods nowadays. In this paper, the structural performances of CFST K-joints with a…
Thermal and structural properties of a hemp–lime biocomposite
2013
Abstract The need to reduce greenhouse gases emission produced by the building sector leads to the research of renewable and less impacting materials that can replace traditional ones. This subject has encouraged new researches on biocomposite concretes with the aim to exploit renewable resources like vegetal fibres intended as materials whose production processes are generally characterized by low costs and energy demand. This biocomposite is obviously much lighter than concrete and, therefore, can be suitably used in such cases where a structure cannot be overloaded, for instance in the realization of a green covering on top of a preexistent building. In this work, a first analysis of the…
Experimental Characterization and Acoustic Correction of a Multipurpose Performance Hall: The Italian Theatre “Cavallino Bianco”
2022
This study presents the retrofit acoustic dq1esign of the Italian theatre “Cavallino Bianco”. In its historical configuration, the hall had a curved roof with a pressed-plant fiber ceiling, which was demolished and replaced with a wooden roof without a false ceiling, leading to an increase in volume and a worsening of the reverberation time. This study proposed the realization of a wave ceiling and the application of sound-absorbing and reflecting panels on the walls, which have already been implemented. These modifications have affected the acoustic characterization of the theatre, as shown both through on-site measurements during the main construction phases and through numerical simulati…
CHP (combined heat and power) retrofit for a large MED-TVC (multiple effect distillation along with thermal vapour compression) desalination plant: H…
2016
Abstract Integrated power plants in “dual purpose” configuration may represent a viable option for energy cost abatement of desalted water produced by MED-TVC (Multiple Effect Distillation along with Thermal Vapour Compression). In this paper an existing large MED-TVC plant with a 36,000 m 3 /day capacity is studied: a plant retrofit is designed, based on a steam power plant with condensation and steam extraction used to drive the steam ejector. As the plant operates in CHP (Combined Heat and Power) mode, the possibility to assess the integrated “CHP + MED-TVC” as high efficiency cogeneration according to Directive 2004/8/EC is discussed. Based on a model developed in Engineering Equation S…